Housing | Stainless steel 1.4404 (316L), Aluminum, Type 6P/ IP66/ IP68 |
Certificates | CE, ATEX, IEC-Ex, FM |
Process Temperature Range | -196°C to +280°C |
Pressure Range | -1 .. +400bar max. |
Supply Voltage | 9.6 … 35 V DC, 2-wire loop |
Measuring Range | Coax 6m |
Material Probe | SS 316 |
Material Sealing | Graphite |
Second line of defense* (optional) | Borosilicate glass GPC 540 with 316L |
Material Isolation | Ceramic |
Signal Output | 4 .. 20mA, 2-Wire |
Communication | HART |
Sensitivity | DK ≥1,4 |
Process Connection | ≥ NPT ¾", ≥ G ¾", different flanges |
Programming | Via display and programming buttons or via HART interface and FDT software. |
• Coax version.
• Works in applications with vapour, buildup, foam generation and condensation.
• Easy setting and diagnosis with control module and display.
• Process temperature up to 280°C.
• Process pressure up to 400bar.
• A variety of approvals available.
• High chemical resistance of the probe.