Oretronic IV Tramp Metal Detector 6A

Sold By :

rjc.co.th



Ramsey Oretronic Tramp Metal Detector Features:

  • Simple installation – no belt cutting, special tools or instruments.
  • Microprocessor-based control unit automates system set-up and calibration.
  • Operator interface provides easy-to-read indicators and simplified setup and system maintenance.
  • Variable frequency eliminates interference from other electrical equipment.
  • Quick Balance electronically balances the coil with the push of a key.
  • Impact-and moisture-resistant PVC coils are mounted on a fiberglass support structure.
  • Offset Swing Arm protects the coils and reduces breakage.
  • Single coil (optional): A single, under-the-belt coil assembly eliminates damage from high burden depths and interference from overhead metal objects.
  • Distance indication (optional): When incorporating a speed sensor, the tramp metal detector’s display shows the distance from the coil to the tramp metal in tenths of feet.
  • Serial communications (optional): Plug in RS-485 communications board.

Additional Features for the Oretronic IV 4 Control:

  • Improved sensitivity.
  • NEMA-4X enclosure.
  • External reset button.
  • Optional RS-485 communication card.

Additional Features for the Oretronic IV 6 Control

  • High sensitivity
  • Painted metal steel enclosure.
  • External reset button.
  • Optional RS-485 communication card.
  • Optional heater for low temperature applications.

Additional Features for the Oretronic III Tramp Metal Detector:

  • Serial communications (RS-485) available as standard to communicate with a remote PLC or remote front panel.
  • Fit for hazardous applications.
Product Size -
Belt Speed 1.5 m/min to 550 m/min (5 ft/min to 1800 ft/min)
Communication Ports Optional RS-485 serial communication
Description Oretronic IV Tramp Metal Detector, 6 Control
Display Type 77 mm x 58 mm viewable LCD graphic display for easy reading, continuous backlit for ease of viewing indoors and outdoors
Enclosure Material Painted mild steel conforms to NEMA-4, IP66 dust and water tight
Enclosure Size 687 mm (27 in) x 524 mm (20.6 in) x 230 mm (9.1 in)
Input/Output Input Power Requirments: 98-253 (fiberglass enclosure) or 115-230 VAC (steel enclosure) VAC, +10%, -15%
50/60 Hz
Single phase, 0.9A (fiberglass enclosure) or 2.8A (steel enclosure)
Output Relay Rating: User supplied 5A max, 250 VAC or 30 VDC
NO and NC Contacts:  Alarm Indicator, Alarm, Marker Output
NC Contacts:  Bypass, Power OK
Operating Temperature -40°C to +58°C (-40°F to +136°F) 
with Optional Heater: -50°C to +58°C (-58°F to +136°F)
Overall Humidity 10% up to 95%, non-condensing
Storage Temperature -30°C to +70°C (-22°F to +158°F)
Certifications/Compliance ISO-9001 Certified
Electronics Switch seletable 115/230 VAC, +10%, -15% 
50/60 Hz 
Single phase, 30 VA, 0.25A