Product
Size |
- |
Communications |
Communication Protocols Profibus-DP |
Ethernet:
Ethernet/IP and Modbus/TCP |
Built-in
USB Port Configuration and data storage |
Expansion
Options, (5) Slots: |
Optional
4-20 mA Out Board (0 to 20 mA or +4 to 20 mA); available in single channel or
dual channel |
Optional
Input/Output Expansion Boards: Relay output board (4 outputs); Opto-22 output
board (4 outputs); DC input board (3 inputs); Opto-22 input board (3
inputs) |
Optional
Digital Input/Output Board (8 inputs/8 outputs) |
Optional
Analog Input/Output Board (2 inputs/2 outputs) |
Profibus
Board or Standard Comms Board |
Description |
Ramsey Micro-Tech 9101 Belt Scale Integrator |
Environmental Conditions |
Operating Temperature -20°C to +60°C (-4°F to
+140°F) |
Environmental
Tolerances: Relative humidity 80% maximum up to +31°C (+88°F) decreasing
linearly to 50% at +40°C (+104°F) |
Altitude
up to 2000 m (6,561 ft); Field Mount suitable for outdoor mounting |
Instrument
Front |
77 mm x 58 mm viewable LCD graphic display for easy
reading, continuous backlit for ease of viewing indoors and outdoors;
Available menu languages include English, German, Italian and Spanish |
Item Description |
Material |
Field
Mount: Reinforced fiberglass housing, NEMA 4X, IP66, dust and
watertight |
Panel
Mount: Chromate mild steel chassis, front panel IP65, DIN 43700 |
|
Dimensions |
Field
Mount: 432 mm (17.01 in) x 360 mm (14.18 in) x 167 mm (6.59 in) |
Panel
Mount: 308 mm (12.11 in) x 102 mm (4.00 in) x 202 mm (7.95 in) |
|
Weight |
Field
Mount: 9 kg (20 lb); Panel Mount: 2.5 kg (5.5 lb) |
Load
Cell Input |
Load cell input circuits (2 each); Number: Up to
six (6) 350-ohm load cells in parallel; Cable distance: 61 m (200 ft) or less
without sense, or 914 m (3000 ft) with sense; Sensitivity: 0.5mV/V to 3.5
mV/V (keyboard selectable); Input Impedance: 1 M-ohm minimum; Maximum Usable
Signal: 114% of 3 mV/V; Internal A/D counts: (3 mV/V): 6,440,000, one open
collector output for pulse total (default) or alarms |
Outputs |
One open collector for pulse output (default) or
alarms |
Power Supply |
Nominal Voltage Field Mount: 100-240 VAC; Panel
Mount: 24 VDC +10%, -15% (user supplied) |
Nominal
Frequency Field Mount: 50/60 Hz; Panel Mount: 24 VDC only, optional AC module
available |
Power
Consumption 50 VA maximum |
Load
Cell Excitation Power Supply 5 VDC ±10%, 90 mA, minimum load impedance (58
ohms) |
Serial
Communication Board |
Standard Serial Interface: RS-232C provides support
for modem; RS-485, 2- and 4-wire multi-drop |
Storage
Temperature |
-30°C to +70°C (-22°F to +158°F) |