VORTEX METER VTX 3

Sold By :

rjc.co.th



VORTEX METER VTX 3

Application:

  • measurement of saturated steam and superheated steam
  • heat quantity measurement of steam and hot water
  • consumption measurement of industrial gases
  • safety-relevant measurements in SIL applications
  • consumption measurement in compressed air networks 

TECHNICAL DATA

Nominal sizeDN15 to DN300 (1/2“ bis 12“)
Process connectionSandwich, Flanges according DIN or ANSI
MaterialStandard:1.4404/316L / Option: Hastelloy C-22
Flow Range0.36 to 1,840m³/h
(0.095 to 486.08 gal/h)
Accuracy±0.75% of measured value
Repeatability-40°C to +240°C
(-40°F to +464°C)
Viscositymax. 100 bar
Process temperature

4-20mA current output HART® (passive),

pulse, Status, frequency, limit switch

Process pressureGraphic display
Ex-protectionATEX II2G- Ex ia IIC T6…T2Gb